No hot water today? Request an urgent quote We use only Solar Victoria authorised and VEU accredited retailers and installers
Heatpump Experts Heatpump Experts

Home / Heat pump hot water

Heat pump hot water, Victoria

Heat pump hot water systems in Victoria

8 systems from Emerald, Midea, Neopower and Rinnai, with specs taken straight from each manufacturer’s data sheet and prices worked out after Victorian rebates. Eligible households replacing gas pay from about $965.

  • 8systems, 270 to 320 L
  • $965lowest price after all rebates, replacing gas
  • R290natural refrigerant in every system we install
  • −7 °Cheat pump operating range on every model

Every system we install, compared

We only list systems we supply and install ourselves, so you can see exactly what you’d be getting. Sorted by tank size.

SystemTankSuitsCOPNoise dB(A)Works fromInstalledAfter all rebates, replacing gas
Emerald 270 L Select E270 L3 to 4 people 4.4150 To confirm$3,180$987
Emerald 270 L Pro270 L3 to 4 people 4.849 (45 in Silent mode) −7 °C$3,473$1,267
Midea Smart Saver 280 L280 L3 to 4 people 4.648 −7 °C$3,136$965
Rinnai Enviroflo 300 L300 Lup to 6 people 8.5*46 (tested at 1.5 m) −7 °C$4,088$1,920
Neopower Black Shield 320 L320 L4 to 6 people 5.442–48 (mode dependent) −7 °C$3,291$1,085
Emerald 320 L Select E320 L4 to 6 people 4.4150 To confirm$3,356$1,150
Emerald 320 L Pro320 L4 to 6 people 5.249 (45 in Silent mode) −7 °C$3,790$1,584
Emerald 320 L Pro E320 L4 to 6 people 5.249 (45 in Silent mode) −7 °C$3,991$1,785

COP and noise are as published by each manufacturer. *Rinnai publishes its COP at 32.6 °C air temperature, while the others use the standard 20 °C test, so it isn’t directly comparable. Prices are indicative, include GST and assume a standard replacement.

How a heat pump heats water

A heat pump works like a fridge in reverse. A fan draws outside air over a coil filled with refrigerant. The refrigerant absorbs heat from the air, even on a cold night, and a compressor squeezes it so its temperature rises. That heat passes into the water in the tank, and the cycle repeats.

Because it moves heat rather than making it, a heat pump uses far less electricity than an element. The measure of this is the coefficient of performance (COP). A COP of 4.8, like the Emerald 270 L Pro, means about 4.8 kWh of heat for every 1 kWh of electricity. A standard electric tank has a COP of 1.

Every system we install uses R290 (propane), a natural refrigerant with a global warming potential of 3, compared with 675 for the older R32. R290 also works well at the higher water temperatures needed to control legionella.

How to choose: the specs that matter

  • Tank size. Get this right first. Too small and the last shower runs cold; too big and you heat water you don’t use. See the sizing table below.
  • Efficiency (COP). Higher is better. Among the systems we install, the Neopower Black Shield (5.4) and Emerald 320 L Pro (5.2) lead. Check the test conditions: most brands test at 20 °C air, but Rinnai publishes its figure at 32.6 °C.
  • Noise. Ranges from 42 dB(A) (Neopower in Silent mode) to 50 dB(A) (Emerald Select). If the unit will sit under a bedroom window, a quiet mode is worth paying for.
  • Cold-weather range. All our systems run the heat pump to −7 °C. With their elements, the Emerald Pro E works to −15 °C and the Midea to −20 °C, useful in Ballarat, Bendigo or the high country.
  • Recovery and boost. How fast an empty tank reheats. The Emerald Pro E’s 1.6 kW Booster gives 108 L an hour, against 58 L an hour on the heat pump alone. It matters for big families with back-to-back showers.
  • Power supply. The Midea and Rinnai plug into a standard 10 A power point. Others are hard wired. If there’s no suitable power point near your old system, an electrician adds one.
  • Warranty. The Neopower and Rinnai both carry a 7-year tank or cylinder warranty and a 5-year warranty on the heat pump parts. Check what labour cover is included.
  • Smart and solar features. Wi-Fi apps, timers and solar modes let you heat water when your panels are producing, which is when a heat pump is cheapest to run.

What size heat pump for your household

Go a size up for long showers, a big bath, teenagers or a spa bath. Read more in heat pumps for 3 to 4 people, heat pumps for 4 to 6 people and our sizing guide.

What a heat pump costs in Victoria after rebates

Three discounts can come off the installed price, applied in this order:

  1. STCs (federal). Every system earns certificates based on its performance and your climate zone. Ours earn 16 to 17 certificates in Zone 4 (most of Victoria) in 2026, worth about $608 to $646. Anyone can get them. Certificate numbers fall each year.
  2. VEU discount (Victorian Energy Upgrades). About $560* whether you replace gas or electric. The building must be at least 2 years old. Renters and landlords can claim it.
  3. Solar Victoria rebate. 50% of what’s left, up to $1,000 ($1,400 for a locally made product), for owner-occupiers with combined income under $150,000 and a property under $3 million.

Worked example: Emerald 270 L Select E, replacing gas

Installed price
$3,180
STCs (about 17)
−$646
VEU discount
−$560
Solar Victoria rebate
−$987
You pay
$987

If you meet each program’s criteria. Rebate rules checked 22 Nov 2026. Read the full rebate guide.

Running costs: the simple maths

Hot water is often the second-biggest energy use in a home. To estimate what a heat pump will use, divide the heat your household needs by the COP.

For example, if your hot water needs 10 kWh of heat a day, an electric element uses 10 kWh of electricity. A heat pump with a COP of 4.4 uses about 2.3 kWh, and one with a COP of 5.4 uses about 1.9 kWh. Multiply by your tariff to get the daily cost. Run it from midday on solar, or on an off-peak rate, and the cost drops further.

This is an illustration, not a prediction. Real use depends on your household, the weather and your tariff.

Installation: what happens on the day

A standard install replaces your old system in the same spot. We deliver the new unit, drain and remove the old one, connect water and power, fit a tempering valve and isolation valves where required, commission the system and lodge the compliance certificate and rebate paperwork.

Things that add cost: a new power point or circuit, moving the system, a new slab, tight or upstairs access, and converting from gas instantaneous (which needs space for a tank). Send us photos from about 2 metres back with your quote and we’ll spot these before we price.

Gas rule. From 1 March 2027, a gas water heater in an existing Victorian home that needs replacing can’t be replaced with another mains gas water heater. See heat pump vs gas.

Brands we install

We don’t own any of the brands whose names or logos appear on this site. We work with these manufacturers and recommend their products based on our own opinion, customer feedback and performance.

Frequently asked questions

How much does a heat pump hot water system cost in Victoria?

The systems we install are $3,136 to $4,088 installed, before rebates. Replacing a gas system, an eligible owner-occupier who gets STCs, the VEU discount and the Solar Victoria rebate pays from about $965 to $1,920. Complex installs cost more.

What rebates can I get for a heat pump in Victoria?

Up to three: STCs (about $608 to $646 for our systems), the VEU discount (about $560*, replacing gas or electric) and the Solar Victoria rebate (50% of what's left, up to $1,000, or $1,400 for a locally made product). Each has its own eligibility rules.

Do heat pumps work in a Victorian winter?

Yes. Every system we install runs its heat pump down to about −7 °C, and their electric elements keep heating below that. Melbourne rarely gets that cold, but recovery is slower on frosty mornings, so we size for winter, not summer.

How much cheaper is a heat pump to run than an electric tank?

A standard electric tank turns 1 kWh of electricity into 1 kWh of heat. A heat pump with a COP of 4 to 5 moves 4 to 5 kWh of heat from the air for each kWh it uses, so it needs roughly a quarter of the electricity for the same hot water. Your saving depends on your tariff and use.

What size heat pump do I need?

As a rule, 3 to 4 people suit 250 to 300 litres and 4 to 6 people suit 300 to 320 litres. Long showers, a big bath or teenagers push you up a size. Our quote asks about your household and recommends a size.

Can I replace my gas hot water with gas after 2027?

From 1 March 2027, a gas water heater in an existing Victorian home that needs replacing can’t be replaced with another mains gas water heater. A heat pump is the usual replacement.

Are heat pumps noisy?

The systems we install are rated between about 42 and 50 dB(A), roughly the level of a quiet office or a fridge hum. Placement matters more than the number: keep it away from bedroom windows where you can.

How long does installation take?

A like-for-like replacement in the same spot usually takes a few hours. Moving the system, adding a power point or converting from gas instantaneous takes longer.

Get the price for your home

Our AI assistant works out the right size, checks your rebates and shows your out-of-pocket price in about two minutes. A qualified heat pump expert reviews every written quote.

Request a quote